· Features and application Z series Large Size DC motor used polygon structure so that the using rate of the stator’s inner space is very high. The magnet yoke is laminated style, suitable for silicon controlled commutate power supply and it can endure pulsating current and rapid change of current (load change).Magnetic poles are fixed by precise orientation. All the motors of system are with compensate winding, so the reverse performance is very well.The insulation class of the motor is F, using of reliable insulation structure and nonmenstruum vacuum pressure impregnated, guaranteeing the stable performance of insulation and good heat dissipation.· Performance 1.Data listed in the technical data sheet should be employed under the following conditions:
a) Altitude above sea level maximal1,000m;
b) Cooling air temperature maximal 40C; Cooling water temperature maximal 32C;
c) The motor can be installed under foul situation, but the right cooling method of cooling method of cooling and defend class must be chosen. If the situation is special, need humid tropic, please negotiate.
d) The motor is suitable for 3-phase bridge style smoothing reactor, also can adopt power supply of DC generator.
e) The motor accord with GB755 “The ration and performance of the rotating electrical machinery”, IEC60034-1 “The ration and performance of the rotating electrical machinery” and JB/T9577 “Technical requirements of Z series middle motor electromotor”;
2. The standard rated voltage of the electromotor are 440V, 550V, 660V, 750V etc. Voltage of other classes can also be derived according specific situation, but must be negotiated when ordering.
3. The basic excitation style is separately excited, the excited voltage is 220V, Voltage of other classes can also be derived according specific situation, but must be negotiated when ordering.
4. Short time overload capacity of motor.
Motor can be divided into two kinds according to the use
First kind (A): ordinary industrial DC motor; Second kind (B): metal rolling mill DC motor.
a) First kind (A) motor can endure the overload (1min) according to table 3
table 3percentage of basic speedpercentage of basic speedseldom usingconstantly using100200175200160150>300140125
b) First kind (B) motor can endure the overload (1min) according to table 4
table 4percentage of basic speedpercentage of basic speedseldom usingconstantly using100200(180*)175(160*)200160(180*)160>300175(160*)140*:When the basic speed of the motor≥650r/min,using the number in the bracket.
c)The short time overload capacity seldom used means happens infrequency or only at the urgency, the motor working exceed the continuous rated overload capacity, we suggest you adjust the instantaneous open/close device of the switch according to the short time overload capacity seldom using.
The short time overload capacity seldom constantly used means it’s an part of the normal working period, the motor endure the continuous rated overload capacity again and again. After working at short time overload, it must working light load to make the overload period’s overload root-mean-square less than its continuous ration.
d)Second kind DC motor(B)can endure the following continuous load; Working continuous within the rated voltage and rotate speed with 115% rated power overload, the temperature is higher when at this overload, other features maybe different from working at the rated condition.
Within the rated voltage and rotate speed, after running at the rated overload, working at the 125% rated power for two hours, the temperature rise can’t overrun the regulated numerical value other features maybe different from working at the rated condition.
e)Second kind DC motor(B),at the rated rotate speed, the overload can reach 2.5 times no longer than 15s only used once in a while.
5. The change rate of current
Under all rotate speed and load, the change rate of current (di/dt) that the motor can endure is 250 times rated current.
6. Libration and noise
a) the libration of the motor accords with GB10068”Measurement evaluation and limits of the vibration severity of rotating electrical machines which the shaft center height is 56mm and above” center standard’s regulation.
b) The noise of the motor accords with GB10069.3 “Measurement of airborne noise emitted by rotating electrical machinery and noise limits”.
7. The efficiencies listed in the data sheet are for rated output, voltage and speed, and include excitation loss.
The choice of the motors’ capacity
1.First kind (A): Ordinary industrial DC motor. The technical data of this kind of motor please see the technical data table. The buyer can decide the capacity, voltage, running speed and the method of cooling of the motor at the buyer’s option.
2. Second kind (B): Metal rolling mill DC motor. The output power of this kind of motor is about 20% lower than kind (A), the detail numerical value can be negotiated by the user and the manufacture.
3. Exclude the specification of technical data in the table. Manufacturer can derive other specification at the requirement of the user.· Model explanation · Structure 1. The methods and defend class of the motor
a) The method of cooling of the motor is separately-cooled, according to the GB/T1993 “Method of cooling of rotating electrical machinery”, there are IC06, IC17, IC37, IC86W. Standard entrance of cooling air is at the end of the main transmission (not the commutator side).The defend class of the motor can be divided into IP23 and IP44 according to the GB/T4942.1 ”the crust defend class of rotating electrical machinery (IP code)”. If the user needs other method of cooling and defend class, it can be negotiated.
b) The relation between the method of cooling and the defend class of the motor please see Table 1
table 1c)The cooling air, air pressure, cooling water flux, motor power see Table 2.
table 2Framebuilt-on blowerair-to-water heat exchangercooling airair pressure
(static pressure)motor powerweightcooling water fluxmotor powerweightm3/hrPakWkgm3/hrkWkgH5001000019007.53001911900H560165002250154002218.51100H71023500240018.5600402×111600
2.The installation and the type of motor according to the GB/T997 “The structure and installation type of rotating electrical machinery”, haveIM1001 (horizontal bottom install, column biaxial) and IM1002 (horizontal bottom install, column biaxial). If the user needs other kinds of installation structure, it must be negotiated.
3. The position of terminal box on standard motor is on the right side when seeing from the main drive end. It can also be installed on the left side, but it must be written in the order contact.
4. The motor using rolling bearing, nonstop adding oil structure.
5.The motor can be installed the following accessories at the user’s option
a) Temperature detector component can be put into the stator winding and bearing room of two side, and connect the outlet wire to the terminal box.
b) The non-drive part of the machine can equipped with tachogenerator, centrifugal starting switch, coder and others which buildup the speed meter protecting device.
c) Heater for preventing condensation can be installed in the motor, but it must be written in the other contact.
6. The air-to-water heat exchanger is usually installed on the top of the motor. If the user wants it to be installed on the side of the motor, the user must put forward it when ordering and settle the assistant upholder by the user himself.
7.The cooler equipped with wind pressure switch, temperature controller, heater for preventing condensation and other protect device.
Z500-2A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
580
610
1300
830
6.8
92.5
40
5800
500
530
1200
835
91.1
425
440
1100
850
90.4
340
350
1000
865
88.1
690
720
1300
980
93.6
600
630
1200
970
93
500
505
1100
980
92
405
410
1000
1010
90.4
740
810
1400
1190
94
620
650
1300
1210
93
510
510
1200
1250
91
Z500-3A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
530
490
1200
765
7.2
91
45
6300
460
415
1100
760
90.3
390
335
1000
790
89.1
310
260
700
805
86.4
620
550
1300
890
92.1
570
490
1200
935
91.5
480
415
1100
960
90.3
370
315
900
945
87.8
720
670
1300
1160
93
630
580
1200
1125
92.1
530
416
1100
1300
91.5
Z500-4A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
540
385
1000
785
8.5
91
55
7200
470
335
900
790
89.1
400
270
800
815
88
329
220
700
860
85.8
640
460
110
920
91.7
560
400
1000
920
91
490
333
1000
975
89.4
380
260
700
960
88
710
510
1200
1145
93
650
430
1000
1280
91
515
345
900
1290
90
Z560-2A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
720
600
1200
1035
7
91.8
150
700
640
520
1200
1050
91.3
550
430
1200
1100
89.7
440
340
1000
1115
87.9
830
720
1300
1180
93.1
760
630
1200
1235
92.3
650
520
1200
1280
91.3
530
410
1200
1320
90.1
890
760
1250
1435
93.2
770
640
1200
1500
92.5
630
510
1200
1555
91.1
935
820
1200
1810
93.2
780
650
1200
1900
92
Z560-3A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
730
600
1200
1040
8.5
91.8
175
7500
650
420
1200
1070
91.3
540
345
1000
1085
89.7
435
270
800
1110
87.9
870
590
1200
1240
93.1
770
510
1200
1255
92.3
660
420
1200
1305
91.3
530
330
1000
1325
90.1
890
610
1250
1430
93.2
760
510
1200
1485
92.5
620
400
1200
1535
91.1
960
660
1200
1860
93.2
790
520
1200
1930
92.1
Z560-4A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
700
380
1100
1020
9
90.3
205
8000
635
335
1000
1055
90
530
275
700
1070
88.6
415
215
700
1075
86
835
470
1200
1240
92.6
800
410
1100
1305
91.9
650
340
1000
1290
90.4
515
265
900
1300
89
900
480
1250
1470
91.9
745
395
1200
1455
92
590
310
1100
1465
90.2
950
525
1200
1845
92.8
770
415
1100
1890
91.6
Z560-5A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
700
310
900
1020
10
90.7
245
9000
640
270
800
1070
89.6
520
220
700
1060
87.7
870
370
1000
1250
92
770
325
900
1255
91.6
640
270
700
1270
90.3
500
210
700
1280
87.4
900
380
1000
1460
92.4
750
480
315
1000
1470
91.6
590
250
700
1470
89.8
900
380
1000
1750
92.5
720
300
900
1780
90.8
Z710-1A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
1100
530
1100
1560
8
93.4
320
10200
970
460
1000
1570
92.9
800
380
900
1570
91.8
640
310
900
1580
91
1500
710
1200
2120
93.9
1300
600
1100
2090
93.7
1100
500
1000
2130
93.3
850
400
800
2080
92.1
1600
770
1100
2560
94.3
1350
640
1100
2600
93.9
1050
500
1000
2550
92.9
Z710-2A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
1150
400
1000
1640
9
92.8
420
11500
1000
345
900
1620
92.7
820
295
800
1610
91.7
650
220
600
1615
90.3
1500
510
1100
2120
93.8
1350
445
1000
2180
93.2
1100
370
900
2140
92.7
870
295
700
2150
91.1
1600
560
1100
2550
94.6
1350
460
1000
2600
93.8
1050
360
900
2550
92.8
Z710-3A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
1100
300
900
1570
10
92.6
510
13000
970
265
700
1580
92.1
800
220
600
1580
91
630
170
500
1580
89.3
1500
390
345
900
2130
93.3
1350
800
2180
93.2
1100
285
600
2150
92.2
850
430
230
500
2170
90.2
1600
900
2560
94.1
1300
350
800
2520
93.1
1050
285
600
2570
92
Z710-4A suitable for IC06, IC17, IC37
IC86W
rating power
rotate speed(r/min)under rating voltage
Max.speed
armature urrent
excitation power
efficiency
running inertia
Weight
kw
750v
660v
550v
440v
r/min
A
kw
%
kg2·m
kg
1100
225
500
1580
13
91.8
630
15000
970
200
500
1590
91.3
800
160
400
1600
89.6
630
125
400
1600
87.9
1500
300
900
2140
93
1300
265
700
2120
92.1
1100
210
500
2190
90.3
850
165
400
2150
88.6
1600
320
800
2580
93.3
1300
265
600
2530
92.6
1050
210
500
2600
90.8
IC86W (ICW37A86), IP44
Mounting dimension
Overall dimendion
Type
A
B
C
D
E
F
GA
DA
EA
FA
GC
H
K
AB
AD
L
L1
HD
AE
h
Z500-1
900
1000
280
160
300
40
169
160
300
40
169
500
42
1090
900
2030
2530
2200
1100
45
Z500-2
1120
2150
2650
Z500-3
1250
2300
2800
Z500-4
1400
2450
2950
Z560-2
1000
1000
315
180
300
45
190
180
300
45
190
560
48
1200
1100
1930
2480
2400
1200
50
Z560-2
1120
2050
2600
Z560-3
1250
2200
2750
Z560-4
1400
2350
2900
Z560-5
1600
2550
3100
IC06, IP23
Mounting dimension
Overall dimendion
Type
A
B
C
D
E
F
GA
DA
EA
FA
GC
H
K
AB
AD
L
L1
HD
AE
h
Z500-1
900
1000
280
160
300
40
169
160
300
40
169
500
42
1090
900
2030
2130
1900
160
45
Z500-2
1120
2150
2250
Z500-3
1250
2300
2400
Z500-4
1400
2450
2550
Z560-2
1000
1000
315
180
300
45
190
180
300
45
190
560
48
1200
1100
1930
2030
2250
190
50
Z560-2
1120
2050
2150
Z560-3
1250
2200
2300
Z560-4
1400
2350
2450
Z560-5
1600
2550
2650
IC06, IP23
Mounting dimension
Overall dimendion
Type
A
B
C
D
E
F
GA
DA
EA
FA
GC
H
K
AB
AD
L
L1
HD
AA
AE
h
Z710-1
1400
1120
355
250
410
56
262
250
410
56
262
710
56
1540
1100
2250
2350
2400
200
1550
40
Z710-2
1250
2380
2480
Z710-3
1400
2530
2630
Z710-4
1600
2730
2830
IC86W (ICW37A86), IP44
Mounting dimension
Overall dimendion
Type
A
B
C
D
E
F
GA
DA
EA
FA
GC
H
K
AB
AD
L
L1
HD
AA
AE
h
Z710-1
1400
1120
355
250
410
56
262
250
410
56
262
710
56
1540
1100
2250
2350
2900
200
1600
40
Z710-2
1250
2380
2480
Z710-3
1400
2530
2630
Z710-4
1600
2730
2830
Products

Z Series Large Size Heavy Duty Industrial DC Motor
Payment Terms: | 30% in advance, balance by T/T or L/C at sight |
Minimum Order: | 1 Piece |
Package: | plywood box |
Brand Name: | ELE |
Protection: | Normal IP23, IP44 (IP54 available) |
Cooling: | Normal IC86W, IC06, IC17, IC37 |
Insulation: | Normal class F (Class H available) |
Mounting: | Normal IMB3 (IM1001 & IM1002) |
Duty: | S1 |
Armature Voltage: | Normal 400V, 440V, 550V, 660V, 750V |
Field voltage: | Normal 220V, 310V |
Ambient condition: | Normal Temperature ≤40℃, Normal Altitude ≤1000m |